A2LA Accredited Calibration |
Download PDF Brochure |
Rubber / Polymer
Chemical
Dimensional
Electrical
Fluid Quantities
Mechanical
Optical Quantities
Thermodynamics
Time & Frequency
Request a Quote
Calibration for Plastic, Rubber, & Polymer Industries
Ash Oven / Muffle Furnace Calibration
| Equipment Types | Supports | ISO 17025 Accredited Measurements |
| Electric Heating Element | ASTM D4574 ASTM D5630 |
Oven Temperature Accuracy / Uniformity |
| Microwave |
Cutting Die Calibration
| Equipment Types | Supports | ISO 17025 Accredited Measurements |
| Specimen-Cutting Dies | Dimensional Verification for All ASTM Tests |
Angle Depth / Height / Length Diameter / Radius Parallel / Squareness |
Durometer Calibration
| Equipment Types | Supports | ISO 17025 Accredited Measurements |
| Durometers | Types: A, B, C, D, DO, E, M, O, OO, OOO, OOO-S | Direct Verification of Force Tip Angle Tip Diameter Tip Radius Indenter Diameter Indenter Length Calibrators Beam Type Durometer Test Blocks |
| Beam-Type Durometer Calibrators | Types: A, D | |
| Durometer Test Blocks |
Environmental Test Chamber / Oven Calibration
| Equipment Types | ISO 17025 Accredited Measurements |
| Cryogenic / CO2 / LN2 Environmental Stress / Thermal Shock Humidity Pressure / Vacuum Salt Spray / Fog High Temperature / Ovens |
Conductivity Humidity Pressure RTD Probes Temperature Accuracy / Uniformity Thermocouples Timers |
Moisture Analyzer Calibration
| Equipment Types | Supports | ISO 17025 Accredited Measurements |
| Moisture Balance | ASTM D6980 | Balance / Scale /
Mass Measurement Temperature Uniformity / Accuracy |
Rheometer Calibration
| Equipment Types | Supports | ISO 17025 Accredited Measurements |
| Mooney Viscometers | ASTM D1646 | Force Tachometer RTD Probes Thermocouples Torque |
| Moving Die Rheometers (MDR) | ASTM D5289 | |
| Oscillating Disk Rheometers (ODR) |
ASTM D2084 | |
| Rubber Process Analyzers (RPA) |
ASTM D5289 ASTM D6204 ASTM D6601 |
|
| Moving Die Processability Testers | ||
| Capillary Die Rheometers | ASTM D3835 ASTM D5099 |
|
| Screw Extrusion Capillary Rheometers | ASTM D5422 |
Scale & Balance Calibration
| Equipment Types | ISO 17025 Accredited Measurements |
| Bench scales Crane scales Filling scales Floor scales Industrial scales Laboratory scales Process scales |
Compression / Tension Balances / Scales / Mass |
Specific Gravity / Density Meter Calibration
| Equipment Types | Supports |
| Density and Relative Density by Displacement | ASTM D792 |
Temperature Controller Calibration
| Equipment Types | Supports | ISO 17025 Accredited Measurements |
On/Off |
Extruders Presses Coolers Ovens Environmental Chambers Benchtop Cryogenic High-temp |
Temperature Measuring Equipment –
TC/RTD Probes Thermocouple Calibration |
Thermocouple Calibration
| Equipment Types | ISO 17025 Accredited Measurements |
| Types B, C, E, J, K, N, R, S, T, U | Thermocouple Calibration |
Resistance Temperature Detectors (RTD)
| Equipment Types | Supports | ISO 17025 Accredited Measurements |
| 3-Wire | (-200 to 800) °C | Resistance Temperature Detectors (RTD) |
| 4-Wire |
Viscoelastic Test Equipment Calibration
| Equipment Types | Supports | ISO 17025 Accredited Measurements | Tensile Testers Universal Testing Machines Universal Tensile Testers Universal Compression Testers |
ASTM E4 ASTM E83 |
Force Measurement – Compression and Tension |
| Extensometers | Extensometer Calibration | |
| Extrusion Plastometers / Melt Indexer | ASTM D1238 | Extrusion Plastometer Calibration |
| Viscosity Meters
for Newtonian Fluids (Viscometers) i.e. Kinematic/Capillary |
Viscosity Meter (Viscometer) Calibration | |
Goodrich Test Equipment Calibration & Maintenance
| Goodrich Cut & Chip Testers | |
| Goodrich Dynamic Stress Relaxometer (DSR) | |
| Goodrich Flexometers | ASTM D623 |
Monsanto Test Equipment Calibration & Maintenance
| Monsanto Rheometer R-100 | ASTM D2084 |
| Monsanto Rheometer R-100S | |
| Monsanto TM-100 | |
| Monsanto Mooney M-1200 | ASTM D1646 |
| Monsanto Mooney M-1300 | |
| Monsanto Mooney M-1500 | |
| Monsanto Mooney M-1500S |
Scott Instruments Test Equipment Calibration & Maintenance
| Scott STI-90 | ASTM D1646 |
Techpro Test Equipment Calibration & Maintenance
| rheoTECH MD+ Techpro moving die rheometers |
ASTM D5289 |
| rheoTECH MDpt Techpro moving die processability testers |
ASTM D5289 ASTM D6204 ASTM D6601 |
| rheoTECH+ Techpro oscillating disk rheometers |
ASTM D2084 |
viscTECH+ |
ASTM D1646 |
| tensiTECH Techpro computerized universal testers and multiple station universal testers |
ASTM E4 ASTM E83 |
| densiTECH II Techpro automatic specific gravity testers |
|
“Best Uncertainty” is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards of nearly ideal measuring equipment.
Best uncertainties represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The best uncertainty of a specific calibration performed by the laboratory may be greater than the best uncertainty due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
Please note the uncertainties achievable on a customer's site can normally be expected to be larger than the Best Measurement Capabilities (BMC) that the accredited laboratory has been assigned as Best Uncertainty on the A2LA Scope.
Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the calibration uncertainty being larger than the BMC.


Contact Us